Merck 105560 TLC Silica gel 60 RP-18 F₂₅₄s 20 Adet/Kutu

Merck 105560 TLC Silica gel 60 RP-18 F₂₅₄s 20 Adet/Kutu 
Aluminum TLC plates, RP-18 modified silica gel coated with flourescent indicator F254s. The RP-18 modified silica gel TLC plates come in a quantity of 20 size 5x7.5 cm for thin layer chromatography applications.
Catalogue Number 105560
Replaces 5560-4; 5560
Overview RP modified plates serve two purposes: act as a pilot method for HPLC and allow to choose various solvent system for special separations. Our RP-modified silica layers are well suited for many separation challenges that unmodified silica cannot overcome. These layers use aqueous solvent systems to separate extremely non-polar substances and analyze particular polar substances that can adapt to ion-pair chromatography. What’s more, RP-modified silica layers are less dependent on atmospheric humidity. Unlike unmodified silica, RP-phases do not exhibit catalytic activity. This makes them the plates of choice for unstable substance that tend to experience oxidative degradation.
Merck 105560 TLC Silica gel 60 RP-18 F₂₅₄s 20 Adet/Kutu 
Product Information
HS Code 3822 19 00
Quality Level MQ100
Applications
Application Aluminum TLC plates, RP-18 modified silica gel coated with flourescent indicator F254s. The RP-18 modified silica gel TLC plates come in a quantity of 20 size 5x7.5 cm for thin layer chromatography applications.
Safety Information according to GHS
Storage class 10 - 13 Other liquids and solids
Storage and Shipping Information
Storage Store at +2 °C to +30 °C.
Specifications
Specific surface area (according to BET; 5-Pt. measurement) 480 - 540 m²/g
Pore volume (N₂-isotherm) 0.74 - 0.84 ml/g
d 50 (laser diffraction, size distribution) 9.5 - 11.5 µm
Layer thickness 150 - 200 µm
Deviation of layer thickness per plate ≤ 30 µm
Chromatographic testings:
A) Cholesterin test
hRf-values
- cholesterin, cholesterin test

28 - 36
B) Steroid test
- methyltestosterone, steroid test 16 - 26
- Reichstein S, steroid test 30 - 40
- hydrocortisone, steroid test 42 - 52
Typical value determined on an activated sheet (120°C, 15 min)
Eluent a) aceton/ water (95/5 v/v)
Eluent b) aceton/ water (60/40 v/v)
Bu ürüne ilk yorumu siz yapın!
Bu ürünün fiyat bilgisi, resim, ürün açıklamalarında ve diğer konularda yetersiz gördüğünüz noktaları öneri formunu kullanarak tarafımıza iletebilirsiniz.
Görüş ve önerileriniz için teşekkür ederiz.
Merck 105560 TLC Silica gel 60 RP-18 F₂₅₄s 20 Adet/Kutu Merck 105560 TLC Silica gel 60 RP-18 F₂₅₄s 20 Adet/Kutu, Merck 105560 TLC Silica gel 60 RP-18 F₂₅₄s LB.M.1055600001
Merck 105560 TLC Silica gel 60 RP-18 F₂₅₄s 20 Adet/Kutu

Tavsiye Et

*
*
*
IdeaSoft® | E-Ticaret paketleri ile hazırlanmıştır.